Many are familiar with Gennex array of solar products – Hybrid Inverters, CanadianSolar PV Modules, Deep-Cycle AGM & Gel Batteries, Multi-Functional Power Gateway, Solar Mount Accessories etc but only a few realize that Gennex actually has its own brand of Online UPS.
Gennex Online UPS is an Uninterrupted Power Supply unit with true double conversion. With a microprocessor control, it optimizes system reliability.
[bctt tweet=”Gennex Online UPS is an Uninterrupted Power Supply unit with true double conversion. With a microprocessor control, it optimizes system reliability.”]
With an output power factor (p.f.) of 0.8 and a wide input range of 110V – 300V, Gennex 2kVA and 3kVA Online UPS features an ECO mode for optimal power saving.
General Features
• True double-conversion
• Microprocessor control optimizes reliability
• Input power factor correction
• Output power factor 0.8
• Wide input voltage (110 V – 300 V)
• Converter mode available
• ECO mode for energy saving (Only available for 1-3KVA)
• Generator compatible
• Smart SNMP works well with either USB or RS-232 together
• Optional isolation transformer available. (Please check sales directly)
Download full datasheet for the Gennex 2kVA & 3kVA Online UPS here.
2kVA Online UPS Specifications
Input
*These Specifications also apply to Gennex 3kVA Online UPS.
Specification | |
---|---|
Nominal Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Input Voltage Range | 55-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC or 160-280VAC (Based on load at 100%) |
Frequency Range | 40 Hz ~ 70 Hz |
Power Factor | ≧0.99 @ Nominal Voltage (100% load) |
Output
*These Specifications also apply to Gennex 3kVA Online UPS.
Specification | |
---|---|
Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Voltage Regulation | ± 1 % |
Frequency Range (Synchronized Range) | 47~ 53 Hz or 57 ~ 63 Hz |
Frequency Range (Battery Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) |
Transfer Time (AC to Battery Mode) | Zero |
Transfer Time (Inverter to Bypass) | 4 ms (Typical) |
Waveform (Batt. Mode) | Pure Sine Wave |
Efficiency
Specification | |
---|---|
AC Mode | 88% |
Battery Mode | 87% |
Battery (*Standard Model)
Specification | |
---|---|
Battery Type | 12 V / 9 Ah |
Numbers | 4 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Charging Current (Max) | 1A |
Charging Voltage | 54.7 VDC ±1% |
Battery (*Long-run Model)
Specification | |
---|---|
Battery Type | Depending on the capacity of external batteries |
Numbers | 4 6 8 6 |
Charging Current (Max) | 1A/2A/4A/6A (Adjustable) |
Charging Voltage | 54.7 VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% 82.1 VDC ±1% |
Indicators
Specification | |
---|---|
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Alarm
Specification | |
---|---|
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
Physical (*Standard Model)
Specification | |
---|---|
Dimension, D x W x H(mm) | 397 x 145 x 220 |
Net Weight (kgs) | 17 |
Physical (*Long-Run Model)
Specification | |
---|---|
Dimension, D x W x H(mm) | 397 x 145 x 220 |
Net Weight (kgs) | 6.8 |
Environment
Specification | |
---|---|
Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) |
Noise Level | Less than 50dB @ 1 Meter |
Management
Specification | |
---|---|
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
[bctt tweet=”With an output power factor (p.f.) of 0.8 and a wide input range of 110V – 300V, the 2kVA and 3kVA Online UPS features an ECO mode for optimal power saving.”]
3kVA Online UPS Specifications
Specification | |
---|---|
Phase | Single Phase with ground |
Capacity | 3000 VA / 2400 W |
Efficiency
Specification | |
---|---|
AC Mode | 90% |
Battery Mode | 88% |
Battery (*Standard Model)
Specification | |
---|---|
Battery Type | 12 V / 9 Ah |
Numbers | 6 |
Typical Recharge Time | 4 hours recover to 90% capacity |
Charging Current (Max) | 1A |
Charging Voltage | 82.1 VDC ±1% |
Battery (*Long-run Model)
Specification | |
---|---|
Battery Type | Depending on the capacity of external batteries |
Numbers | 8 |
Charging Current (Max) | 1A/2A/4A/6A (Adjustable) |
Charging Voltage | 109.4VDC ±1% |
Indicators
Specification | |
---|---|
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Alarm
Specification | |
---|---|
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
Full Specification Sheet
Download full datasheet for the Gennex 2kVA & 3kVA Online UPS here.
Price
Gennex 2kVA Online UPS costs 112,000 naira while the 3kVA model costs 142,000 naira.
Contact 08171936361, 012934490 or visit our office to buy the Gennex 2kVA & 3kVA Online UPS.